Release:
2024. Vol. 10. № 2 (38)About the authors:
Alexander Ya. Gilmanov, Cand. Sci. (Phys.-Math.), Senior Lecturer, Department of Modeling of Physical Processes and Systems, School of Natural Sciences, University of Tyumen, Tyumen, Russia; a.y.gilmanov@utmn.ru; ORCID: 0000-0002-7115-1629Abstract:
Maintaining the soil in a frozen state in a cryolithozone is necessary for preventing the collapse of structures. The most effective technical solution for this is the use of two-phase passive heat stabilizers. Monitoring the state of permafrost soil allows to accept technical decisions that prevent soil thawing. Calculation the effective parameters of such decisions requires mathematical modeling of thermal and hydrodynamic processes. An approach is proposed to effectively compensate the heat flux from the pile on the ground, assuming the location of the heat stabilizer in the same well with the pile or at a slight distance from it. The aim of the work is to calculate the effective parameters of the heat stabilizer depending on its location relative to the pile. The developed mathematical model assumes the five tasks: 1) blowing the above-ground part of the heat stabilizer with air; 2) movement of liquid refrigerant to the bottom of the heat stabilizer; 3) cooling of the casing of the heat stabilizer with an two-phase flow of refrigerant; 4) heat exchange in the system refrigerant — the casing — frozen soil; 5) compensation of heat flow from the pile into the ground with heat flow from the ground into the heat stabilizer. The first problem is solved on the basis of an empirical criterion equation. The second and third tasks are solved using the laws of conservation of mass, momentum and energy. The fourth and fifth tasks involve solving the equation of thermal conductivity. As a result of calculations, the effective parameters of the heat stabilizer were obtained. The minimum lateral dimensions of the heat stabilizer casing have been established to compensate the heat flow from the pile into the ground. The time of freezing front reaching the pile from the heat stabilizer located at a distance of 0.5 m from one of its corners has been determined.Keywords:
References:
Ageev, S. E. (2019). Application of two-phase thermosyphons in industrial heat recovery and transfer systems. Innovation Science, (5), 14–16. [In Russian]
Anikin, G. V., & Mochalov, D. V. (2020). Estimating the efficiency of HET systems using carbon dioxide and ammonia as refrigerants. Earth’s Cryosphere, 24(2), 48–51. [In Russian]
Anikin, G. V., & Ishkov, A. A. (2022). Use of analytical solution of functioning of the “HET” system for express estimation of the efficiency of its work. Earth’s Cryosphere, 26(4), 59–67. https://doi.org/10.15372/KZ20220405 [In Russian]
Anikin, G. V., & Ishkov, A. A. (2023). Analytical solution of the problem of operation of deep seasonal cooling devices to assess their efficiency. Earth’s Cryosphere, 27(4), 37–44. [In Russian]
Ishkov, A. A., & Anikin, G. V. (2020). Mathematical model of functioning of systems of temperature stabilization of soils with a horizontal evaporator. Applied Physics and Mathematics, (5), 12–16. https://doi.org/10.25791/pfim.05.2020.1173 [In Russian]
Ishkov, A. A., & Anikin, G. V. (2021). Mathematical modeling of the functioning of soil temperature stabilization systems with a horizontal evaporator. Oilfield Engineering, (2), 53–59. https://doi.org/10.33285/0207-2351-2021-2(626)-53-59 [In Russian]
Kislitsin, A. A. (2002). Fundamentals of thermophysics. University of Tyumen. [In Russian]
Nigmatulin, R. I. (1987). Dynamics of multiphase media: in 2 parts. Part 1. Nauka. [In Russian]
Sahin, V. V., Gerliman, E. M., & Brykov, N. A. (2019). Heat transfer in examples and tasks. Baltic State Technical University. [In Russian]
Cao, J., Chen, C., Su, Y., Leung, M. K. H., Bottarelli, M., & Pei, G. (2019). Experimental study on the temperature management behaviours of a controllable loop thermosyphon. Energy Conversion and Management, 195, 436–446. https://doi.org/10.1016/j.enconman.2019.05.031
Ding, T., Cao, H. W., He, Z. G., Wu, J. D., & Li, Z. (2020). Experimental study on a loop thermosyphon cooling system in data centers using CO2 as a working Fluid, especially thermal environment and energy-saving effect. Applied Thermal Engineering, 175, Article 115359. https://doi.org/10.1016/j.applthermaleng.2020.115359
Ding, T., Chen, X., Cao, H., He, Z., Wang, J., & Li, Z. (2021). Principles of loop thermosyphon and its application in data center cooling systems: A review. Renewable and Sustainable Energy Reviews, 150, Article 111389. https://doi.org/10.1016/j.rser.2021.111389
Fisenko, S. P. (2022). Film flow of the heat-transfer agent in a closed thermosyphon. Journal of Engineering Physics and Thermophysics, 95(6), 1421–1425. https://doi.org/10.1007/s10891-022-02610-y
Gao, J., Lai, Y., Zhang, M., & Chang, D. (2018). The thermal effect of heating two-phase closed thermosyphons on the high-speed railway embankment in seasonally frozen regions. Applied Thermal Engineering, 141, 948–957. https://doi.org/10.1016/j.applthermaleng.2018.06.061
Gao, J., Ma, Q., & Ren, J. (2021). Evaluating the heating performance of a novel heating two-phase closed thermosyphon (HTPCT) in high-speed railway embankments of seasonally frozen regions. Arabian Journal of Geosciences, 14(22), Article 2256. https://doi.org/10.1007/s12517-021-08641-8
Guo, L., Yu, Q., Yin, N., You, Y., Wang, J., Sun, Y., & Chen, K. (2024). Two-phase closed thermosyphon-induced frost jacking of piles and foundation instability in a thawed permafrost area. Natural Hazards, 120, 619–637. https://doi.org/10.1007/s11069-023-06169-6
Juengjaroennirachon, S., Pratinthong, N., Namprakai, P., & Suparos, T. (2017). Performance enhancement of air conditioning using thermosyphon system’s energy storage unit for cooling refrigerant before entering the condenser. Journal of Mechanical Science and Technology, 31(1), 393–400. https://doi.org/10.1007/s12206-016-1241-z
Kukkapalli, V. K., Kim, J.-H., & Kim, S. (2021). Optimum design of thermosyphon evaporators for roadway embankment stabilization in the arctic regions. Journal of Mechanical Science and Technology, 35(10), 4757–4764. https://doi.org/10.1007/s12206-021-0941-1
Moustaid, M., Platel, V., Guillet, M., Reynes, H., & Buttay, C. (2022). Modeling and test of a thermosyphon loop for the cooling of a megawatt-range power electronics converter. International Journal of Thermofluids, 13, Article 100129. https://doi.org/10.1016/j.ijft.2021.100129
Pinate, W., Rittidech, S., & meena, P. (2018). Critical heat flux of a two-phase closed thermosyphon with fins. Journal of Mechanical Science and Technology, 32(5), 2357–2364. https://doi.org/10.1007/s12206-018-0447-7
Plotnikov, A. A. (2020). Stabilizing the temperature regime of a frozen foundation bed using thermal insulation and cooling mechanisms. Soil Mechanics and Foundation Engineering, 57(4), 329–335. https://doi.org/10.1007/s11204-020-09674-z
Qin, D., Yao, T., Ding, Y., & Ren, J. (2021). Introduction to cryospheric science. Science Press. https://doi.org/10.1007/978-981-16-6425-0
Wang, F., Li, G., Ma, W., Mu, Y., Mao, Y., & Wang, B. (2018). Influence of warm oil pipeline on underlying permafrost and cooling effect of thermosyphon based on field observations. In W. Wu, & H. S. Yu (Eds.), Proceedings of China-Europe Conference on Geotechnical Engineering. Springer Series in Geomechanics and Geoengineering (pp. 1424–1428). Springer. https://doi.org/10.1007/978-3-319-97115-5_115